E N G L I S H
Mandrel Installation (without POP NUT™ Mandrel Release, DPN277-185)
1.
Disconnect the Air Supply
2.
Select the correct Mandrel according to Table 5.
3.
Remove the Nose Housing from the tool to expose the Mandrel and Spin Pull Head Case (Figure 5).
4.
Pull the Lock Pin Holder back and unscrew the Mandrel by turning it counter-clockwise.
5.
While holding the Lock Pin Holder back, screw in the desired mandrel until it stops.
6.
Release the Lock Pin Holder.
Note: If the Lock Pin Holder does not return to its original position then turn the Mandrel counter-clockwise to ensure
the Lock Pin engages the Mandrel and the holder moves forward.
7.
Replace the Nose Housing.
Nosepiece Installation
1.
Disconnect the Air Supply
2.
Select the correct Nosepiece according to Table 5.
3.
Remove the current Nosepiece from the tool by loosening the Lock Nut and unscrewing it.
4.
Remove the Lock Nut from the Nosepiece
5.
Thread the Lock Nut onto the desired Nosepiece
6.
Screw the Nosepiece into the Nose Housing
7.
Lock it in place by tightening the Lock Nut against the Nose Housing (Refer to the Mandrel & Nosepiece Adjustment in
the Basic Tool Operation section for adjustment).
16
POP NUT™
Mandrel Release
PUSH
Figure 4: POP NUT™ Mandrel Release
Noise Housing
Mandrel
Mandrel
Figure 5: Mandrel Installation
Mandrel
Spin Pull Head Case
Lock Pin Holder
PULL
Mandrel Adapter