light turns yellow. When another fault occurs and it has not been confirmed, the light turns yellow and
flickers. The fault indicator light works together with the fault prompt tone.
-
EARTH FAULT: this light is turns yellow if a earth short fault of some speaker circuits occurs.
-
SYSTEM FAULT: this light is turns yellow if the configuration file is wrong, or the versions of the software
and hardware does not match.
-
RUNNING: when the system starts operating, this light turns green and flickers.
-
NETWORK FAULT: the light turns yellow if a communication fault between the ZS-2000M and other
broadcasting devices occurs, such as network communication fault or FAS communication fault.
-
DISABLED: this light turns yellow when a loudspeaker circuit is automatically disabled due to a short
circuit.
-
DELAY: when a fire alarm signal is received and the time delay is activated, the time delay indicator light
turns green. When the ZS-2000M enters the voice alarm state, the light turns off.
The time delay indicator light turns green if the ZS-2000M broadcasting time delay is activated.
The light turns off when the broadcasting time delay finishes or the DELAY button is pressed.
Figure 4 Schematic Diagram of the ZS-2000M Special Function Buttons
-
RESET: when the system fails, press the RESET button to reset the current system state. All fault
indicator lights return to normal and the fault prompt tone stops.
-
ALL: selects all zones. Press once to select all zones and then press the button again to cancel the
selection.
-
FAULT: fault state confirmation button. When another system fault occurs, press the FAULT button to
confirm the existence of the fault. The fault prompts tone stops and the fault indicator light turns yellow..
-
CLOSE: the button used to stop broadcasting.
-
SELF TEST: Used to check all indicator lights, buzzers, and built-in loudspeakers to check the equipment
operation status.
After pressing the SELF-TEST button, all indicator lights turn on or flicker, the fault buzzers buzz
continuously, and the built-in loudspeakers play the self-test voice.
The ZS-2000M performs uniform management of the ZS-1500/ ZS-2250/ ZS-4125 and other equipment.
The self-test function does not affect the normal operation of other functions..
-