INSTRUCTION MANUAL
READ THE INSTRUCTION MANUAL CAREFULLY BEFORE
Scrupulously follow the safety instructions given in the
generator manual.
The guards and mobile parts of the wire feeder casing
must be in position before connecting the welding machine to
the power supply.
- Replacing the feeder and/or wire guide;
- Inserting the wire into the feeders;
- Loading the reel of wire;
- Cleaning the feeders, gears and the area below them;
- Lubricating the gears.
AND DISCONNECTED FROM THE MAINS.
- Do not use the handle to hang the welding machine.
2. INTRODUCTION AND GENERAL DESCRIPTION
This wire feeder must be connected to an electric generator that
welding.
adjustment and the regular feeding of the 4-roll wire feeder unit
alloy steel with CO
2
the workpiece to be welded.
3. TECHNICAL DATA

3.1 DATA PLATE

The main data regarding wire feeder use and performance are given
in the data plate and have the following meaning:
production.
2- Power supply line symbol.
3- Casing protection rating.
4- Welding circuit performance:
2
welding machine can supply the corresponding current.
5- Power supply line characteristic data;
- U
: Wire feeder alternate power supply voltage.
1
1
search).
and numbers; the exact values of the welding machine technical data
plate.
The main data regarding wire feeder use and performance are given
in table 1 (Tab.1).
GB
mixes using full or
2
Fig. A
OTHER TECHNICAL DATA
The weight of the wire feeder is given in table 1 (Tab. 1).
5. INSTALLATION
FROM THE MAINS.
THE ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED
OUT BY EXPERT OR QUALIFIED TECHNICIANS.
PREPARATION
Unpack the wire feeder.
When connecting to the power network scrupulously follow the
indications given in the generator manual.
MACHINE IS OFF AND DISCONNECTED FROM THE MAINS.
Connecting the welding current return cable
Connect the cable to the piece to be welded or the metal bench on
worked.
Connect this cable to the clamp with the symbol (-).
Connecting the torch
locking ring nut manually. Prepare the torch to receive the wire for
exiting easier.
only).
- Connect to the current generator:
- control cable to the relative 14-pole connector.
- Connect the gas hose coming from the wire feeder to the cylinder
pressure reducing valve and tighten with the supplied strip.
version only)
data of the cooling unit corresponds to the mains voltage and
- The cooling unit must only be connected to a power supply system
with neutral conductor connected to earth.
relative coupling (female 5-pole). Connect the free end of the
be connected to the power supply protective ground wire (yellow-
green).
Both the plug and socket must have the rated voltage and current