Using the air conveyor extension 3
Depending on the thickness of the roof, it may or may not be necessary to use the air conveyor
extension in a correct manner between the air conditioner outlet air opening and the diffuser.
For roofs with a thickness of 30 mm using the air conveyor extension is not necessary.
For roofs with a thickness of 70 mm using the air conveyor full extension is necessary.
For roofs between 30 mm and 70 mm the modified air conveyor extension is necessary: cut to length
using the cutting lines preprinted on the plastic.
Fasten with self-tapping screws 5.
Move the air diffuser 2 closer to the fixing frame 4 and connect the wirings between the air conditioner
and the infrared receiver and the MIN-MAX button.
Securely fasten the air diffuser 2 to the fixing frame 4, using the nuts 7.
Make sure you have properly modified the air conveyor extension 3: if it is too high, you may
run into the problem described where the diffuser, during the fixing phase, deforms due to
interference with the extension itself.