Descargar Imprimir esta página

Electrical Connections - Indel B SW PLEIN AIRCON 12V Instrucciones De Montaje, Uso Y Mantenimiento

Ocultar thumbs Ver también para SW PLEIN AIRCON 12V:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ELECTRICAL CONNECTIONS

Electrical connections should be made only by qualified technicians.
Connect the power cables to the air conditioner only AFTER completing the installation of the
unit, to verify operation.
12 V operation (standard mode), connected to the service battery.
A
No accessories needed.
The air conditioner can work if the vehicle is either stationary or moving.
For electrical connections, simply route the power cables to the services battery and use an 80
A fuse for protection.
Make connections as shown in the wiring diagram.
B) 12 V and 230 V operation (optional mode), connected to the service battery and the mains.
Equipping a 230 V Smart Switch transformer kit, cod. Z999/1250 (optional) is necessary.
The air conditioner can work if the vehicle is either stationary or moving.
For electrical connections, please refer to the instructions supplied with the kit cod. Z999/1250.
REF.
Q. T Y
DESCRIPTION
1
1
Control board A
2
1
Control board B
2.1
2
Mains fuse 15 A
3
1
Infra red receiver + LED
4
1
Ambient temperature probe
5
1
Exchanger probe
6
1
DC-DC converter
7
1
Hermetic compressor
8
1
Hermetic compressor control unit
9
1
Condenser electric fan
66
REF.
10
11
12
13a
13b
18
19
20
21
SW PLEIN AIRCON 12V
Q. T Y
DESCRIPTION
1
Evaporator electric fan
-
Service battery
1
Mains fuse 80 A
-
Communication cable connector
(control board side B)
-
Communication cable connector
(DC-DC converter side)
1
MIN-MAX button
1
Green LED (MIN)
1
Red LED (MAX)
-
Power cable connection

Publicidad

loading