Battery Replacement
UPS User´s Manual
This UPS is designed with easy battery replacement.
Please follow below steps to replace the inside batteries.
Step 1: Turn o the equipment that is plugged into the output of the UPS.
Step 2: Turn o the UPS.
Step 3: Remove AC input plug of the UPS from the AC wall outlet.
Step 4: Remove all equipment from the output sockets of the UPS.
Step 5: Remove the battery cover by pushing down the front panel.
Step 6: Disconnect the battery connector. Then, slide out the existing battery pack from the UPS by
grasping the battery pull tap.
Caution - Do not short the positive wire and negative wire of battery.
Caution - DO NOT pull the battery pack out by pulling on the battery wires.
Step 5
Step 7: Slide the new battery pack into the UPS.
Step 8: Verify proper polarity. Re-connect the battery connectors together.
NOTE- Some sparking might occur and this is normal.
Step 9: Reinstall the battery cover onto the UPS. Now, the UPS is ready for normal operation.
NOTICE: Properly dispose of the old batteries at an appropriate recycling facility or return them to the
supplier in the packing material for the new batteries.
Step 6