Fig. 4: Example with pneumatic supply plate

10.3 Identifying the modules

10.3.1 Material number for valve system

Fig. 5: Position of the material number
The material number for the complete valve system (16) is printed on the right
end plate. You can use this material number to reorder an identically configured
valve system.
Note that, after a valve system conversion, the material number still refers to
u
the original configuration
Conversion

10.3.2 Address table for PLC configuration

For PLC configuration, you need the address table corresponding to your configu-
ration. The number of the address table for your IO-Link interface can be found
on the name plate on the right end plate.
Note that, after a valve system conversion, the address table still refers to the
u
original configuration
Conversion
17
Address-Data: 7
Fig. 6: Example of rating plate with address table
17
Address table number
Address tables
Table 8: Example address table (address table 7)
Valve position
14 coil
1
Coil 1 (X.0)
2
Coil 3 (X.2)
3
Coil 5 (X.4)
4
Coil 7 (X.6)
AVENTICS™ | R412018154-BAL-001-AA | English
6
6
P
16
documentation.
documentation.
12 coil
Coil 2 (X.1)
Coil 4 (X.3)
Coil 6 (X.5)
Coil 8 (X.7)
Valve position
14 coil
5
Coil 9 (X+1.0)
6
Coil 11 (X+1.2)
7
Coil 13 (X+1.4)
8
Coil 15 (X+1.6)
9
Coil 17 (X+2.0)
10
Coil 19 (X+2.2)
11
Coil 21 (X+2.4)
12
Coil 23 (X+2.6)
13
Coil 24 (X+2.7)

10.4 Conversion of the valve zone

The symbols for the valve zone components are explained in section "Valve
zone".
The extension circuit boards of a configured valve system use length-opti-
mized boards according to the configuration.
Subsequent shortening is not possible. If necessary, the base plate area has to
be replaced by extension base plates after the 2nd valve position.
You may use the following components for the extension or conversion of the
system:
• Base plate extension kit (multipole version)
• Pneumatic supply plate extension kit (multipole version)
• Combination plate extension kit (multipole version)

10.4.1 Sections

The valve zone of a valve system can consist of multiple sections. A section al-
ways starts with a supply plate that marks the beginning of a new pressure zone.
The first section is always a minimum of 2 valve positions long.
6
2
10
11
1
10
IO-Link
P
MIN
S1
Fig. 7: Example valve system, consisting of three sections.
1
IO-Link interface
6
Pneumatic supply plate
11
Base plate, 3x
15
Supply plate extension kit
17
Extension base plate, 3x, with multi-
pole board
S1
Section 1, multipole extension
(factory configuration)
S3
Section 3, multipole extension
(subsequent extension)
P
Pressure supply
The valve system in Fig. 7 consists of three sections:
Table 9: Example valve system, consisting of three sections
Section
Components
Section 1
Minimum
• Pneumatic supply plate (6)
configura-
• Two base plates, 2x (10)
tion
• IO-Link interface multipole board (2)
• 2 valves (18)
Extension
• Base plate, 3x (11)
• Two base plates, 2x (10)
• Multipole board, 7x (13)
• 7 valves (18)
12 coil
Coil 10 (X+1.1)
Coil 12 (X+1.3)
Coil 14 (X+1.5)
Coil 16 (X+1.7)
Coil 18 (X+2.1)
Coil 20 (X+2.3)
Coil 22 (X+2.5)
-
-
NOTICE
13 10 6
11
10
15
13
P
P
S2
2
IO-Link interface for 2 valves
10
Base plate, 2x
13
Multipole board
16
Extension base plate, 2x, with multi-
pole board
18
Valve
S2
Section 2, multipole extension
(factory configuration)
MIN
Minimum configuration
IO-
Power and signal supply
Link
18
17
16
S3
22