SPECIFICATIONS
Gas category: Direct Pressure – Butane-Propane mixture. Canister
must conform to the EN417 or AS2278 standard. This appliance is only
intended for use with 100g/230g/450g Jetboil Jetpower Isobutane/
Propane Fuel Canisters (sold separately). It may be hazardous to
attempt to fit other types of gas containers.
Jet Size: 0.27mm Gas Consumption: 7 MJ/hr (AU) || 139 g/hr [2 kW]
(EU) || 9,000 BTU/hr (CA)
Minimum Storage Temperature: -40°F / -40°C
Minimum Use temperature: 0°F / -20°C
LEAK CHECK
PROCEDURE
1. Perform leak checks outside, in a well-ventilated area.
2. Connect fuel canister (3.1) to valve (3.2) by threading in the
orientation shown in Fig 4.
3. Put soapy water on the gas connection between fuel canister and
the valve. Formation of bubbles indicate a gas leakage.
Do not check for leaks using a flame.
If a leak is detected, do not attempt ignition. Remove fuel
canister immediately and contact Customer Service.
4. If no leak is found, detach fuel canister. Leak check is complete.