WARNING
Installation and maintenance must be carried out by suitably qualified
personnel only. Hazardous voltages may be present on the connection terminals.
Installation
This product is intended to be installed in accordance with the operating and installation
requirements of Overvoltage Category II and Pollution Degree 2 (as defined by IEC 664).
It must be fitted in a suitable enclosure which is accessible to qualified personnel only.
An external supply fuse must be fitted. The recommended fuse is:
DC supply - S504-2A manufactured by Bussmann.
Fuse details: Antisurge 2A, Rating 50V , Breaking capacity 35A @50V, UL recognised
(file no E75865), complies with IEC127.
AC supply - S504-200mA manufactured by Bussmann.
Fuse details: Antisurge 200mA, Rating 250VAC , Breaking capacity 35A @250VAC, UL
recognised (file no E75865), complies with IEC127.
The relay output circuits must be fitted with fuses suitable for the voltage and current
being switched.
Maximum fuse ratings:
250VAC
@ cosØ= 1
fuse rating 5A
30VDC
@ cosØ= 1
fuse rating 5A
All conductors carrying hazardous voltage should have external switching or disconnect
mechanisms fitted which provide at least 3mm of contact separation in all poles.
Failure to install or operate the unit in accordance with the above requirements
may result in the electrical safety of the unit being impaired.
Maintenance
Ensure that all power sources to the unit are isolated prior to maintenance,
inspection or cleaning.
There are no user serviceable parts inside this unit. Under no circumstances should the
case be opened.
All external wiring connections should be inspected at regular intervals. Any damaged
wiring should be replaced and any loose connections should be retightened.
Cleaning should be carried out using a dry cloth to wipe the casing of the unit.
Programming
Caution: If the optional relay output and/or analog output board(s) are installed in
the DPM, then entering Program mode will cause both relays to release and the analog
output to go to its minimum value (0V or 4 mA) regardless of the input signal value.
2
Diagnostics
Caution: Performing the diagnostic tests will turn on the analog output and
operate the relays if those options are installed. First remove power from the DPM and
disconnect the outputs from any loads that should not be turned on. If the optional RS485
communication board is installed, the DPM will respond with the scaled input value to the
QST command.
ACHTUNG
INSTALLATION UND WARTUNG DÜRFEN NUR VON ENTSPRECHEND
GESCHULTEN MITARBEITERN VORGENOMMEN WERDEN. AN DEN
ANSCHLUSSKLEMMEN KÖNNEN LEBENSGEFÄHRLICHE HOCHSPANNUNGEN
ANLIEGEN.
Installation
Dieses Produkt ist gemäss den Betriebs- und Installationsanforderungen von
Schutzklasse II und Funkstörklasse 2 (entsprechend der Definition durch IEC 664) zu
installieren.
Es muss in einem geeigneten Schutzbereich aufgestellt werden, der nur für entsprechend
geschulte Mitarbeiter zugänglich ist.
In die externe Versorgung muss eine Sicherung eingesetzt werden. Empfohlen werden
Sicherungen vom:
Versorgung DC - S504-2A, zB hergestellt von Bussmann.
Kenndaten der Sicherung: Absicherung gegen Stromspitzen 2A, Sicherungsbemessung
50V, Ausschaltleistung 35A bei 50VAC, anerkannt durch UL (Aktenzeichen E75865),
entspricht IEC127.
Versorgung AC - S504-200mA, zB hergestellt von Bussmann.
Kenndaten der Sicherung: Absicherung gegen Stromspitzen 200mA,
Sicherungsbemessung 250VAC, Ausschaltleistung 35A bei 250VAC, anerkannt durch UL
(Aktenzeichen E75865), entspricht IEC127.
Die Ausgangsschaltkreise des Relais müssen mit geeigneten Sicherungen entsprechend
den geschalteten Spannungen und Strömen versehen werden.
Maximale Sicherungsnennwerte:
250VAC
@ cosØ= 1
Sicherungsnennwert 5A
30VDC
@ cosØ= 1
Sicherungsnennwert 5A
Alle Stromleiter, an denen gefährliche Spannungen anliegen, müssen mit externen
Schalt- oder Trennvorrichtungen versehen werden, die einen Kontaktabstand von
mindestens 3 mm an allen Polen herstellen.
Wenn das Gerät nicht entsprechend den vorstehenden Anforderungen installiert
und betrieben wird, ist die elektrische Sicherheit des Geräts nicht gewährleistet.
3