5.8

Aborted Welding Process

The welding process has failed if a plain-text error is dis-
played on the screen and the audible signal buzzes con-
tinuously. An error has to be acknowledged by pressing
the STOP/RESET key.
5.8

Cooling Time

The cooling time as given in the fitting manufacturer's
instructions has to be respected. If the bar code provided
by the fitting manufacturer contains cooling time data,
it will be displayed at the end of the welding process and
will be counted down to zero. This countdown can be ac-
knowledged and canceled at any time by the STOP/RESET
key. However, note that for that time the pipe fitting joint
which is still warm must not be subjected to an external
force. No cooling time is displayed if the fitting code does
not contain any such information.
5.10

Returning to the Start of Parameter Input

After welding is finished, disconnecting the welded fitting
from the unit or pressing the STOP/RESET key will reset the
unit back to the start of entering the welding parameters.
6
Additional Information in the Welding
Report
Every welding report saved to system memory, which can
be downloaded as a PDF report file or in the DataWork
format, contains a number of welding and traceability data
that the operator can decide to enter or not to enter in
the set-up menu.
6.1
Entering Preformatted and User-defined
Traceability Data
All traceability data enabled in the configuration menu at
"Data Recording" (see Sect. 9) have to be entered before
the welding process. The welding unit prompts the user to
enter them either before or after entering the fitting bar
code (see Display 2). Depending on what data is entered,
either its repeated input is mandatory (e. g., the welder
ID code; see Sect. 5.2) or previously entered data can be
changed and confirmed or confirmed without changes
(e. g. the commission number; see Sect. 6.2).
Certain traceability data can also be accessed quickly, via
a selection screen, by pressing the ï cursor key (see Dis-
12
EN
HÜRNER HST 300 GeoTherm + 2.0 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
***
Recording
Welder Code
>Commission Number
Version September 2022
***