Descargar Imprimir esta página

Emergency Off; Heater Coil Error; Power Supply Failure At Last Welding; Technical Specifications - HURNER HST 300 GeoTherm+ 2.0 Manual De Instrucciones

Ocultar thumbs Ver también para HST 300 GeoTherm+ 2.0:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany

10.2.8 Emergency Off

The welding process has been interrupted by pressing the
STOP/RESET key.

10.2.9 Heater Coil Error

The dynamic current value during welding differs by more
than 15% from the required value, indicating a short-circuit
in the heater coil.

10.2.10 Power Supply Failure at Last Welding

The last welding is incomplete. The welding unit was dis-
connected from the power supply voltage while it was
in progress. To go on using the unit, this error has to be
acknowledged by pressing the STOP/RESET key (see also
Sect. 9.4).
12
Technical Specifications
Operating Range
Nominal Voltage
Frequency
Output Power
Ingress Protection
Primary Current
Ambient Temperature
Output Voltage
Max. Output Current
Memory for Welding Reports 500 reports
Data Interface Port
(see also the information on the data ports in Sect. 8)
Tolerances:
Temperature
Voltage
Current
Resistance
13

Service and Repair Contact

HÜRNER Schweisstechnik
Nieder-Ohmener Str. 26
35325 Mücke, Germany
Web: www.huerner.de
We reserve the right to change technical specs of
the product without prior notice.
Info
Version September 2022
fittings of 20 - 75 mm
230 V
50 Hz / 60 Hz
1600 VA, 80 % duty cy.
IP 54
max. 16 A
– 20°C to + 60 °C (– 4°F to + 140°F)
8 V - 48 V
60 A
USB v 2.0 (480 mbit/s)
± 5 %
± 2 %
± 2 %
± 5 %
Tel.: +49 (0)6401 9127 0
Fax: +49 (0)6401 9127 39
E-mail: info@huerner.de
HÜRNER HST 300 GeoTherm + 2.0 User's Manual
21
EN

Publicidad

loading