2.3
Securing the Fitting and the Joint
Use positioner clamps or a vice to secure the fitting and the
joint to be made before welding. The fitting manufacturer's
installation instructions, local and national regulations have
to be respected in all cases.
A welding process must never be repeated with the same
fitting, since this may cause parts under power to be acces-
sible to the touch.
2.4
Cleaning the Product
The product must not be sprayed with or immersed in water.
2.5
Opening the Unit
The cover of the product should be removed only by
trained, specialized staff. Unprofessional opening
will result in danger of bodily harm or for life. Feel
Caution
free to request information on our authorized ser-
vice partner in your area at the address in Sect. 13.
2.6
Extension Cables on the Worksite
To extend power cord length, use exclusively properly ap-
proved extension cables that are labeled as such and have
the following conductor sections:
up to 20 m:
1.5 mm² (2.5 mm² recommended);
over 20 m:
2.5 mm² (4.0 mm² recommended);
When using the extension cable, it has always to be
rolled off completely and lie fully extended.
Caution
2.7
Checking the Product for Damage
Before every use of the product, check safety features and
possibly existing parts with minor damage for proper func-
tion. Make sure that the push-on connection terminals work
properly, that contact is fully established, and that the con-
tact surfaces are clean. All parts have to be installed correct-
ly and properly conform to all conditions in order for the
product to function as intended. Damaged safety features
or functional parts should be properly repaired or replaced
by an approved service shop.
2.8
Data Interface Cover Cap
The dust cap for the interface has to cover the port during
operation, in order to keep humidity and contaminations
away.
6
EN
HÜRNER HCU 300 User's Manual
H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
type H07RN-F
type H07RN-F
Version September 2022