11.1.10 Service Due
The recommended next service date for the welding unit is
overdue. The service due message has to be acknowledged
by pressing the START/SET key. Send the welding unit to the
manufacturer or an approved service point for service and
check-up.
11.1.11 Input Error
A code that was entered is incorrect. At manual welding pa-
rameter input, no welding time was entered. An incorrect
value was selected in the date setting.
11.1.12 Memory Full
The system memory is full of welding reports. Print or down-
load the reports in memory or switch memory control off.
Without memory control, a new report overwrites the old-
est existing one.
11.1.13 Downloaded Cancelled
During data transfer or printing, an error condition occurred
which could not be cleared.
11.2
Errors During Welding
All errors that occur while welding is in progress are also in-
dicated by an audible alarm.
11.2.1
Low Voltage
The input voltage is below 175 volts. If the error condition
persists for longer than 15 seconds, the welding process will
be aborted. If the voltage goes down below 170 volts, the
welding process will abort immediately.
11.2.2
Overvoltage
The input voltage is over 290 volts. If the error condition
persists for longer than 15 seconds, the welding process will
be aborted.
11.2.3
Resistance Error
The resistance value of the connected fitting is out of the
read tolerance.
11.2.4
Frequency Error
The frequency of the input voltage is out of tolerance
(42 Hz - 69 Hz).
11.2.5
Voltage Error
Check generator voltage and current. The output voltage
22
EN
HÜRNER HCU 300 User's Manual