Introduction

The voltage tester 45217 is universally applicable tester for voltage testing, continuity
testing, rotary field testing and trip test of RCD. The tester is constructed according to
the latest safety regulations and guarantee safe and reliable working.
The voltage tester 45217 is characterized by the following features
Designed to meet international safety standards. IEC 61243-3:2014
Measurement category (CAT.) IV 600 V, III 1,000 V
AC and DC voltage test from 0,5 V to 1,000 V AC and 1,500 V DC
Polarity indication
Single-pole phase test
Phase rotation test
Trip test of RCD
Continuity test
Resistance test
Auto Power ON / OFF
Torch light
IP64 (IEC 60529)
Vibration motor
TRMS
After unpacking, check that the instrument is undamaged. The product
package comprises
1x Tester 45217
2x 4 mm test tip adapters
2x CAT III/ 1,000 V test tip cover
2x Batteries 1.5 V (AAA, IEC LR03)
1x Instruction manual

Safety measures

The testers have been constructed and tested in accordance with the safety
regulations for voltage testers and have left the factory in a safe and perfect con-
dition. To maintain this condition, the user must observe the safety instructions
in this manual.
The operating instructions contain information and References required for
safe operation and use of the tester. Before using the tester, read the operating
instructions carefully and follow them in all respects.

Danger of electric shock and other dangers

To avoid an electric shock, observe the precautions when working with voltages
exceeding 120 V (60 V) DC or 50 V (25 V) eff AC. In accordance with DIN VDE
these values represent the threshold contact voltages (values in brackets refer to
limited ranges, e.g. in agricultural areas).
The tester must not be used with the battery compartment open.
Before using the tester, ensure that the test lead and device are in perfect wor-
king order. Look out e.g. for broken cables or leaking batteries.