Battery replacement

Remove the probes from any testing point, when opening the battery case.
Batteries are empty when the continuity test with both test probes connected
cannot be done anymore. A battery symbol in the LCD indicates low battery.
Follow the procedure below and replace batteries with new ones (type IEC
LR03 1.5 V).
Unscrew the battery door using Philips type screwdriver.
Pull out the battery door and replace the batteries. Insert new batteries accor-
ding to the engraving on the battery door.
Re-assemble battery door.
Confirm that the battery door case is properly locked prior to measurements.

Technical data

Voltage range
LED nominal voltage
LED tolerances
ELV indication LED
Response time
LCD range
LCD resolution
LCD accuracy
Crest factor
LCD overrange indication
Peak current
Measurement duty
Internal battery consumption approx. 80 mA
Single-pole phase test
voltage range
Phase rotation test
Continuity test
NCV test
Resistance measurement
Frequency measurement
Battery
Diode test
Temperature
Humidity
Altitude
Overvoltage
Standard
Pollution degree
Protection
0.5 V...1,000 V AC True RMS (16 2/3...950 Hz), 0.5
V...1,500 V DC(±)
12/24/50/120/230/400/690/1,000 V, AC (16 2/3�950 Hz),
DC(±)
according to EN 61243-3
> 50 V AC, > 120 V DC
< 0.5 s (LED); < 1 s (LCD)
0.5 V...1,000 V AC, 1,500 V DC
0.1 V(< 10 V) and 1 V (> 10 V)
3 % + 3 digit > 10 V, 3 % + 5 digit < 10 V
1 ... 10V: CF > 2.5 / >10 ... 300 V: CF=5 / >300V�500V:
CF=3 / >500V�750V: CF=2 / >750V CF=1.5
"OL"
Is < 3.5 mA (at 1,000 V)
30 s ON (operation time), 240 s OFF (revocery time)
100�1,000 V AC (40...70 Hz)
170�1,000 V phase-to-phase, AC 40...70 Hz
detection range 0�500 kΩ + 50 %
100...1,000 V AC against earth (50/60 Hz)
detection range 0�1,999 Ω ± (5 % + 10 dgt); resolution:
1 Ω
1...950 Hz +/- (5 % + 5-digit); resolution: 1 Hz; 10...1,000
V AC
3 V (IEC LR03 1.5 V x 2)
0...2 V (+/- 5 % 10-digit); resolution: 0.01 V
-15�50 °C operation; -20�60 °C storange, No
condensation
max. 85 % RH
up to 2,000 m
CAT. III 1,000 V / CAT. IV 600 V
EN 61243-3:2014
2
IP64
EN
19