INSTALLATION
INSTALLATION - INSTALACIÓN
Cavo-Cable
I
3 x1xH05VV-F
L
N
CLASS "A" GROUND
FAULT CIRCUIT INTERRUPTER
F
CONNECTING THE CONTROL UNIT
EN
Power supply terminal: 120-240Vac
1
4-way connector for Touch panel K101U (optional)
2
Terminal for external panel (optional)
3
LED light connector
4
The connections to terminals
that need to be made by the installer. Refit the cover on the
electrical box.
For information on connecting the control unit, follow the
terminal board instructions. The primary
circuit cables must be duly separated in line with
2
3
4
the precautions for SELV circuits.
CL -> LED cable: already wired, standard length 1m
A
CP -> Touch panel cable K101U: supplied with product
B
(max. distance 5m)
CPE -> External button strip cable (optional): Double insulation,
C
3 poles, section of conductors 0.5 - 1 mm
diameter 1/4" - 1/2" (maximum distance 393 11/16")
CA -> Power supply cable: cable H 05 VV-F, 3 poles (L – N
D
– GND), wire cross-section 1mm
Touch panel K101U (optional)
F
External panel (optional)
G
Main circuit breaker switch
I
RGB: RGB LED light
L
The input for the buttons are separate extra-low voltage (SELV).
For information on connecting the control unit, follow the
terminal board instructions. The primary
circuit cables must be duly separated in line with
2
3
4
the precautions for SELV circuits.
Note: in order to complete the
plugs in the cable glands must be removed. If connection is
not required, do not remove such plugs, as they guarantee the
box IPX4 protection degree as far as water sprays.
Maximum operating temperature: 104°F.
D
B
are the only ones
1
2
3
4
and secondary
1
, external
2
.
2
and secondary
1
and
connections, the
2
3
1
2
A
(factory setting)
No external panel
COM – IN1 open
COM and IN2 open
(De configuration d'usine)
Sans boîtier de commande
externe
COM – IN1 ouvert
COM et IN2 ouvert
(De fábrica)
Sin panel externo
COM – IN1 abierto
COM e IN2 abierto
44
L RGB
A
C
3
4
G
B
Connection 2 N.O. buttons
Connect, with 3x cable (0.5-1mm
the cable ends:
COM – IN1: (LIGHT function)
COM – IN2: (COLOR-FEEL function)
Raccordement 2 boutons NA
Raccorder avec le câble 3x (0.5mm-
q÷1mm2) les bornes respectives
COM – IN1 : (Fonction LIGHT)
COM – IN2 : (Fonction COLOR-FEEL)
Conexión de n°2 botones NA
Conecte con cable 3x (0.5mm-
q÷1mm2) los extremos respectivos
COM – IN1: (Función LIGHT)
COM – IN2: (Función COLOR-FEEL)
L
),