8. MANUFACTURER'S CONTACT DETAILS
Company Name:
Address:
Telephone:
9.
TECHNICAL SPECIFICATION
Applianace Category
Reference gas
Inlet pressure
Injector diamater
Gas consumption
Nominal Heat Input (Hi)
Nominal Heat Input (Hs)
Safety device
Gas control valve
Flexible hose (4 m)
Name:
Address:
Tel/fax:
Date of sale:
Name:
Address:
Tel/fax:
Date of purchase:
The gas fireplace should be installed by a qualified Installer in accordance with the applicable national building
regulations and in accordance with the guidelines contained in the Installation and User's Manuals.
I hereby declare that having read the User's Manual and the Guarantee Conditions.
Name:
Address:
Tel/fax:
Date of commissioning:
I hereby declare that the gas fireplace installed by my Company has
been installed in accordance with the applicable building regulations
and in accordance with the guidelines contained in the Installation and
User's Manuals.
The installed gas fireplace is ready for safe operation.
Planika Sp. z o.o.
Bydgoskich Przemysłowców 10
+ 48 52 364 11 60
I3P
G31
[mbar]
30
37
[mm]
1,4
[kg/h]
0,5
0.55
[kW]
6,4
7
[kW]
7
7,7
Date and legible signature of the Buyer
50
30
0,65
0,5
8,3
6,4
9,0
8
Thermocouple
BS190
Ø9mm
SELLER
BUYER
INSTALLER
15
I3B/P
G30
G30
37
50
28-30
1,4
0,55
0,65
0,5
7,8
9,1
7,4
8,5
10
Seller's seal and signature
Installer's seal and signature
I3+
G31
37
1,4
0,55
7,4
8
8