Descargar Imprimir esta página

Pre-Operation Check; Operation; Starting The Engine - CAMPAGNOLA ENERGY4 Manual De Uso Y Mantenimiento

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 60
5.4

PRE-OPERATION CHECK

WARNING!
If any item in the Pre-operation check is not working properly, have it inspected and repaired before operating the
generator. The condition of a generator is the owner 's responsibility. Vita! components can start to deteriorate quickly
and unexpectedly, even if the generator unused.
Verification of the condition of Generator is the responsibility of the owner.
Pre-use checks must be made each time the Generator is used.
Before use, check the fuel level (see par. 5.2), top up if necessary.
Before use, check the engine oil level (see par. 5.3), top up if necessary.
Before use, check that the generator does not have oil leaks.
In case of anomalies not described in this manual, contact an authorized workshop.

6 OPERATION

WARNING!
Never operate the engine in a closed area or it may cause unconsciousness and death within a short time. Ope-
rate the engine in a well ventilated area.
Before starting the engine, do not connect any electric devices.
The generator has been shipped without engine oil. Do not start the engine till fill with the sufficient engine oil (see
par. 5.3).
Do not tilt the generator when adding engine oil. This could result in overfilling and damage to the engine.
The generator can be used with the rated output load at standard atmospheric conditions:
-
Ambient temperature:
-
Barometrie pressure:
-
Relative humidity:
The output of the generator varies due to change temperature, altitude (lower air pressure at higher altitude) and hu-
midity.
The output of the generator is reduced when the temperature, the humidity and the altitude are higher than standard
atmospheric conditions.
Additionally, the load must be reduced when using in a confined areas, as generator cooling is affected.
6.1

Starting the engine

1- Turn the air vent knob to "ON"
2- Turn the fuel cock
3- Move the choke lever
The Generator is ready to be started.
Use and maintenance manual – Translation of
original Instruction Rev.: 00, Date 01/03/2022
Recommended engine oil:
Recommended engine oil grade:
Engine oil quantity:
25°C
100kPa
30%.
;
to position A;
to position B;
SAE SJ 15W-40
API Service SE type or higher
0.31 L
Page 33

Publicidad

Solución de problemas

loading