Descargar Imprimir esta página

SICK PowerProx - WTT12L Manual De Instrucciones página 21

Ocultar thumbs Ver también para PowerProx - WTT12L:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
4.4
Alignment
8018110.1D62/2022-08-19 | SICK
Subject to change without notice
Figure 2: B
Only apply voltage/switch on the power supply (U
have been established. The green LED indicator lights up on the sensor.
Operation in IO-Link mode: Connect the device to a suitable IO-Link master and inte‐
grate in the master or control via IODD/function block. The green LED indicator flashes
on the sensor. IODD and function block are available to download from www.sick.com
under the order number.
Explanations of the connection diagram (Graphic B):
Teach-in = external teach-in (ET) (see Adjustment)
TI / Test = test input (see Additional functions)
C = communication (e.g., IO-Link) (see Additional functions)
L/D = light/dark switch
Align the sensor with the object. Select the position so that the red emitted light beam
hits the center of the object. You must ensure that the optical opening (front screen)
of the sensor is completely clear [E]. We recommend making the adjustments using an
object with a low remission.
2.
1.
Figure: E
OPERATING INSTRUCTIONS
> 0 V) once all electrical connections
v
O P E R A T I N G I N S T R U C T I O N S | PowerProx - WTT12L
en
21

Publicidad

loading