22/38
Assembly
Required accessories
• Stop gate VE 2,
see catalog TS 2.
• Sensor
IEC/EN 60947-5-2-2004,
3 842 537 995 (F).
1.
Mount the stop gates
(2 x VE 2) and the
proximity switches
(S 1, S 2, S 3) on the
section profi le.
Testing functionality
1.
Starting position:
Pre-stop gate (VE
)
1
open, main stop
gate (VE
) closed; lift
2
rotate unit in the lower
end position.
2.
S1 actuated by passing
WT 2: VE (VE
) closes.
1
3.
S2 actuated by WT 2:
Cylinder moves to upper
end position, WT 2 is
lifted.
4.
Switch upper end
position actuated:
Rotation 90 ° or 180 °.
5.
End position rotation
reached: if required,
start operation.
6.
If required, complete
operation, external
signal: Cylinder moves to
lower end position, WT 2
is lowered.
7.
Switch lower end
position actuated: Main
stop gate (VE
) opens.
2
8.
S3 actuated by WT 2:
Main stop gate (VE
)
2
closes, pre-stop
gate (VE
) opens
1
(starting position).
Bosch Rexroth AG, MIT: HD 2, 3 842 358 735/2019-10
7.5.5
Assembling WT 2 control parts
S1
A
Fig. 10:
Assembling stop gates and proximity switches
0,3
S3
B
S2
358 735-09