VOX SETTING
(long press)
1.
Long press the VOX key (10) to
current setting and its value appear on the display. Three parameters allow
to adjtust the VOX: Sensitivity
time
.
2a. Turn the ROTARY knob (6) or use the UP/DN key (13) on the microphone
modify
the current parameter then, press the F key (9) to
to
parameter or....
2b. Press first the F key (9) to
select
ROTARY knob (6) or use the UP/DN key (13) on the microphone to
the current parameter.
3.
When all adjustments are done, press PTT switch (12) to
KEY BEEP function is activated, a long beep sounds to
of the operation (consul the KEY BEEP menu page 46).
4.
If no key is pressed for 10 seconds, the unit automatically
VOX SETTING without save.
-
Sensitivity
: allows the adjustment of the microphone (original one
or optional vox) for an optimum transmission quality. Adjustable level from1
(high level) to 9 (low level). Default value: 5.
-
Anti-Vox
: allows disabling the transmission generated by the sur-
rounding noise. The level is adjustable. AF (according the squelch level)
and from 0 (without anti-vox) to 9 (low level). Default value: AF.
-
Delay time
: allows avoiding the sudden cut of the transmission by
adding a delay at the end of speaking. The level is adjustable from 1 (short
delay) to 9 (long delay). Default value: 1.
VOX SETTING doesn't activate the VOX function.
11) 6 PIN MICROPHONE PLUG
The plug is located on the front panel of the transceiver and makes the
setting of the equipment into the dashboard easier.
See Cabling Diagram page 73.
12) PTT (Push To Talk)
Transmission key, press to
transmit
to
listen to
an incoming communication,
TOT (Time Out Timer)
If the transmission using PTT switch (12) or VOX function is longer than 3
minutes, the display starts blinking and the transmission ends. A beep will
sound until the PTT switch (12) key is released.
enter
the VOX SETTING. "VOX" blinks, the
/ Anti-vox level
/ Vox delay
select
another the parameter and then turn the
store
and exit. If the
confirm
the success
exits
the function
a message,
is displayed and release
disappears.
13) UP/DN BUTTONS ON MICROPHONE ~ SCAN
UP/DN BUTTONS ON MICROPHONE
Press UP/DN buttons (13) on the microphone to
increase
and DN to
See ROTARY KNOB page 43.
next
SCAN
(very long press)
Press and hold the UP or DN button (13) for ± 7 seconds or until a beep
modify
sounds (consult the KEY BEEP menu page 46) to
tion. "SCN" appears on the display. The scanning stops as soon as there is
a busy channel. Consult the SCAN TYPE menu page 47. In
mode, turn the ROTARY knob (6) or press the UP/DN buttons (13) on the
microphone to
change
Press PTT switch (12) to
§ SKIP page 43.
5 + 9) KEY LOCK
(EMG + F keys)
Long press simultaneously the EMG (5) and F (9) keys to
the KEY LOCK function. When the function is active, "
display.
A) DC-POWER TERMINAL (13.2 V / 26.4 V)
B) ANTENNA CONNECTOR (SO-239)
C) JACK FOR OPTIONAL VOX MICROPHONE (Ø 2.5 mm)
D) PA SPEAKER JACK (8 Ω, Ø 3.5 mm)
E) JACK FOR EXTERNAL OPTIONAL SPEAKER (8 Ω, Ø 3.5 mm)
C) FUNCTIONS TURNING ON THE UNIT
1) FREQUENCY BAND SELECTION
(Configuration: EU; PL; d; EC; U; In)
The frequency bands have to be chosen according to the country of use.
Don't use any other configuration. Some countries need a user's licence.
See table page 75.
1.
Turn on the power while pressing the F key (9). The letter corresponding to
the current configuration is blinking.
2.
In order to change the configuration, use the ROTARY knob (6) on the unit
or the UP/DN buttons (13) on the microphone.
44
(short press)
change
decrease
the channel.
activate
scan direction.
exit
SCAN. "SCN" disappears on the display. See the
activate/deactivate
the channel. UP to
the SCAN func-
SCANNING
" appears on the