CT(E), CTLP, CT(E)S, CTW
7
Electrical connection
!
WARNING!
Have the electrical connection carried out by an electrician.
A
NOTICE!
• Do not connect the cassette toilet to the voltage supply directly in
parallel with other power-consuming devices.
• Do not connect the control of the cassette toilet to a pressurized
water pump.
• The rated capacity of an external water pump should not exceed
60 W.
I
NOTE
• The external water pump is not included in the scope of delivery.
• A pre-fuse is not necessary, because the cassette toilet is internally
fused.
7.1
Models CT(E)4xxx, CTLP4xxx, CT(E)S4xxx with
external water pump
A
NOTICE!
• The rated capacity of an external water pump should not exceed
60 W.
• The 12 V connection cable must have a cross-section of at least
1.5 mm
• A 7.5 A automotive fuse is integrated in the toilet control.
1. Connect the cassette toilet via the main terminal block of the vehicle to its own
power supply (fig. n, page 16).
2. Connect the external water pump (fig. o, page 17).
EN
²
.
Electrical connection
29