Descargar Imprimir esta página

Dometic CT 4050 Instrucciones De Montaje página 31

Ocultar thumbs Ver también para CT 4050:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
CT(E), CTLP, CT(E)S, CTW
7.2
Model CTW4xxx with integrated water pump
A
NOTICE!
• The 12 Vg connection cable must have a cross-section of at least
0.75 mm
• The current consumption of the pump should not exceed 2 A.
• A 7.5 A automotive fuse is integrated in the toilet control.
1. Connect the cassette toilet via the main terminal block of the vehicle to its own
power supply.
2. Make the plug connections between control and operating panel and the
cassette tank.
Circuit diagram for integrated water tank and water pump (fig. q, page 19):
No.
1
2
3
4
5
6
7
8
7.3
Model CTE4110
Wiring diagram (fig. r, page 19):
No.
1
2
3
EN
²
.
Designation
Reed switch: Tank status 3/4 full
Reed switch: Tank status 1/1 full
Micro-switch: Position of cassette tank
®
With SOG
only: Reed switch for SOG
®
With SOG
only: SOG
®
With SOG
only: SOG
Reed switch: Freshwater indicator
Internal water pump
Designation
Reed switch: Tank status 1/1 full
Solenoid valve control
Silicon power diode 5 A / 50 V
®
control
®
control solenoid in the slide opening handle
®
fan
Electrical connection