Installation (continued)
Resetting the motor unit to its default
position
If the motor unit has moved because of an earthquake, for example,
follow the procedures below to fix its position.
1
Set the micrometer value for the motor unit to 3.
2
Conduct steps 1–3 in "Removing the motor
unit" on page 19.
3
Adjust the motor unit position.
Push in the motor unit until there are no spaces between it, the
platter and the spacer block.
4
Follow the installation procedures from step 19
(on page 18) to remove the tools.
5
Set the micrometer value for the motor unit as
desired.