Using the device
current ensures that a battery which
is not used for a long period of time
will still be able to be charged.
If the revival is not successful after
10 minutes, then "Err" will be shown
on the display.
If a 24 V charging program is
selected accidentally and a 12 V
battery is connected, then after
10 mins, "Err" will appear on the
display.
z Selecting programs
Note:
Before a charging program is car-
ried out, the battery must be con-
nected to the charger as described
in the "Connection" section. The
charging process continues automat-
ically. Depending on the program
selected, the charging characteris-
tics for voltage, time and tempera-
ture are
monitored. The charging process
contains a diagnosis program,
a revival mode and a trickle charge
function.
Program
1
12V
1
2
12V
1
3
12V
2
90
GB/MT
max.
max.
(V)
(A)
14.4 V
5.0 A
14.7 V
5.0 A
14.4 V 10.0 A
4
12V
2
5
24V
1
6
24V
1
7
24V
2
8
24V
2
9
12V
10
24V
Program 1
12V
1
(14.4 V / 5.0 A)
To charge 12 V batteries with a
capacity of 20 Ah to 100 Ah.
Press the program selector button
once to select Program 1.
The
and
12V
3
shown on the LC display. During the
charging process, the charging
display
flashes. The progress of
9
the charging process (1-4 bars) will
be shown on the status display
When the battery is fully charged,
the status display shows
The flashing stops and the device
switches to trickle charging automat-
ically. The display will show "FUL".
14.7 V 10.0 A
28.8 V
2.5 A
29.4 V
2.5 A
28.8 V
5.0 A
29.4 V
5.0 A
13.6 V
3.0 A
27.2 V
1.5 A
8
symbols are
4
1
.
10
4 bars.