In TIG welding, only direct polarity must be used, placing the welding torch on the negative pole. In addition,
a gas bottle (M), normally Argon, must be placed in the installation and connected to the machine through a
pressure reducer (N) as shown in the figure below.
THE USE OF HIGH-FREQUENCY AND HIGH-VOLTAGE IGNITION DEVICES MAY
3.5.2 ADJUST AND PARAMETERISATION OF TIG WELDING PROCESS
4. MAINTENANCE OPERATIONS. RECOMMENDATIONS.
In order to provide a long life for the equipment,
we must follow some fundamental rules of
maintenance
recommendations.
Gala Gar, S.L. c/ Jaime Ferrán, 19 (Políg. Cogullada) | Tel.: (+34) 976 47 34 10 - 50014 ZARAGOZA |
TIG WELDING WITH MANUAL GAS CONTROL.
DAMAGE THE EQUIPMENT.
Press the encoder for 5 seconds to switch between
processes (MMA, Pulsed MMA or TIG).
Select TIG process Pulsed
5"
Press the encoder to switch between the parameters to
be set.
Turn it to adjust the parameter.
For the TIG process, 1 parameterisation menu is
available: Amps.
WELDING CURRENT
Turn the encoder to set the desired output current.
(20 to 120 amps)
and
use.
Follow
+ −
GOOD MAINTENANCE OF THE EQUIPMENT WILL
PREVENT A LARGE PERCENTAGE OF
these
21/49