this screen, it is possible to access the configuration menu,
in which the default behavior of the welding machine can
be configured. To access it, press the MENU key and then,
on the following screen, enter the access code using the cur-
sor keys or hold the transponder card in front of the RFID
reader.
To enter information using the cursor keys, proceed
as follows: The ï and ð cursor keys position the
cursor at the desired digit/character on the display
Info
screen. The ñ and ò cursor keys are used to select
the value (letter, number) that should appear at
this place. In general, the START/SET must then be
pressed to confirm that input.
Pressing the ñ and ò cursor keys in the menu that appears
(Display 4), you can select a menu option, then access the se-
lected sub-menu by pressing the MENU key again.
In the Machine Data sub-menu, the type of machine (its des-
ignation and its cylinder section) to which the control and
data logging/reporting unit is connected, has to be defined
(see the arrow symbol in Display 5, where a basic machine
chassis of 315 mm with a cylinder section of 5.89 cm² is be-
ing selected). This selection is made by pressing the ñ or ò
cursor keys and confirmed, by pressing the START/SET key.
For added safety, the section of the selected machine's cyl-
inder is once more displayed and has to be confirmed again
by START/SET.
An access code is required to open the Machine Data sub-
menu. This code will be disclosed only to authorized person-
nel with the operating company.
If the wrong machine is selected in this menu, all
pressure computations by the machine will be
wrong! Changing to another machine requires consul-
Important
tation with the manufacturer or an authorized service
shop, as a sensor calibration is then also recommended.
Performing this step requires proper authorization.
As an addition to the preinstalled machines, user-defined
machine types can be set as needed at the unused menu
entries (a designation for the machine and the cylinder sec-
tion of its clamping chassis have to be entered).Enter the re-
quired data using the cursor keys and confirm by START/SET.
From the Configuration Menu's Sensor Parameters option,
the temperature sensor (PT100, PT1000) and the pressure
sensor (160 bar, 250 bar, 600 bar) can be selected/calibrated
(see Display 6).
Use the ñ or ò cursor keys to select the desired item and
Version November 2022
HÜRNER SPG 2.0 User's Manual
Settings
-M-
>Reporting
-M-
Sensor Parameter-M-
Machine Data
-M-
Display 4
Code: 415311
HST 200
3.16
HST 250
5.10
>HST 315
5.89
HST 355
6.60
Display 5
SENSOR PARAMETERS
>Calib. Heat.El. -M-
Calib. Press.S. -M-
Display 6
Calib. Press. Values
[SET]
Act. Pres. : 80.0bar
Nom. Pres. : 00.0bar
Display 7
EN
11