H Ü R N E R S c h w e i s s t e c h n i k G m b H
Nieder-Ohmener Str. 26
35325 Mücke, Germany
"Automode on" means that in the Weld Control mode the
Automode feature for the easy management of the
welding process (see Sect. 4.3.4) can be used, "off," that
the feature is not available.
"Weld Pipe Segments on" means that at parameter input
before welding, either a straight-pipe joint or a joint of
pipe segments at an angle or tees etc. can be selected,
"off," that this selection is impossible, hence that on-
ly straight pipe-to-pipe welding operations can be per-
formed.
"Check Ambient Temperature on" means that the outside
temperature is measured before welding, "off," that it
is not; if the temperature is below 0°C (32°F), welding
should be performed only after taking appropriate pre-
cautions (heating, tent, for instance).
"Welder Code Options – M – " means that by pressing the
MENU key, the user can access a sub-menu that allows
determining when the welder code, if it is enabled un-
der "Recording," has to be entered: always, i. e. before
evey single welding operation, only before the first
welding operation after switching the unit on or only
before the first welding operation of a new day/date.
"Language – M – " means that by pressing the MENU key,
the user can access a sub-menu for selecting the display
and report language (see Sect. 4.1.3).
"Date/Time – M – " means that by pressing the MENU key,
the user can access a sub-menu for setting the clock (see
Sect. 4.1.4).
"Buzzer Volume – M – " means that by pressing the MENU
key, the user can access a sub-menu for setting the vol-
ume of the status buzzer (see Sect. 4.1.5).
"Temperature Unit – M – " means that by pressing the
MENU key, the user can access a sub-menu for selecting
centigrade or Fahrenheit as the unit for the tempera-
ture.
"Pressure Unit – M – " means that by pressing the MENU
key, the user can access a sub-menu for selecting bars or
pounds per square inch (psi) as the unit for the pressure.
"Length Unit – M – " means that by pressing the MENU key,
the user can access a sub-menu for selecting millimeters
or inches as the unit for the length.
"Inventory Number – M – " means that by pressing the
MENU key, the user can access a sub-menu for entering
the number under which the unit is inventorized inter-
nally with the operating company.
"Number of Tags – M – " means that by pressing the MENU
key, the user can access a sub-menu for entering the
number of tags that are printed automatically after
welding with the optional label tag printer if such a
printer is connected.
"Standard – M – " means that by pressing the MENU key,
the user can access a sub-menu for selecting the stan-