4.11.2 Menu 5 + Menu 6: Force limits for opening and closing
Crush hazard at the door!
WARNING
If the force limits are set too high, there is a risk of personal injury.
The factory setting is "6" for opening and "4" for closing.
NOTICE
1. Select menu item "5".
ð After approximately 2 seconds, the display flashes and the set value for
the force limit for opening appears.
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) but-
tons.
3. Press the programming button (PROG button)  (D). The display shows  "6".
After approximately 2 seconds, the display flashes and the set value for the
force limit for closure appears.
4. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) but-
tons.
5. Press the programming button (PROG button) (D).
ð The display shows "7".
4.11.3 Menu 7: Adjusting the light phases
1. Select menu item "7".
ð After approximately 2 seconds, the display flashes and the set value for
light time appears. The factory setting is "0".
2. If desired, adjust the setting with the aid of the OPEN (B) and CLOSE (C) but-
tons.
Value
0
1
2
3. Press the programming button (PROG button) (D).
ð The display shows "8".
64 - EN
The force on the main closure side must not exceed 400  N  /
750 ms!
We recommend performing door adjustments according to
menu 8 before carrying out the force learning cycle.
Light time
30 s
60 s
90 s