26. Adjust the air pressure inlet regulator control of the equipment (No.5 Fig.1) by turning it
counter clockwise.
27. Open the bleed tap (No.15 Fig.1)
12.3. Antipulsations filter
(DM 1/300 part list No.14 and 04 in DM 1/400 part list)
1. Empty the product from the equipment and perform the decompression procedure.
2. Unscrew the cover of the antipulsations filter.
3. Extract the product filter (DM 1/300 part list No.16 and 27 in DM 1/400 part list) and clean
it with the suited solvent or replace it if necessary.
4. Assemble the product filter.
5. Assemble, by tightening to the utmost, the cover of the antipulsations filter.
The gun can be cleaned with solvents or detergents in a spray gun
washing machine.
If you opt for this cleaning system, we advise you take into account the following considerations,
which, if not applied, may damage the gun and render the warranty null and void:
- Do not submerge the gun in solvent or detergent longer than the time
required for cleaning.
- Do not use the gun immediately after cleaning has been completed.
- Ensure that there is no solvent or detergent inside it and that it is
completely free of these.

13. Maintenance

Before starting to work, verify the state of the product hoses and the connections of the ele-
ments through which the product flows.
In order to carry out maintenance or repairs, first disconnect the unit from the compressed air
distribution network.
Never move the unit by dragging it by the hoses.
Do not apply excessive force or inadequate tools for maintaining and cleaning the unit. Some
repairs must be done with special tools on some occasions. In these cases, you must contact
the SAGOLA's Customer Service. Any handling of this product by non-authorised personnel will
render the warranty null and void.
The unit must be overhauled on a regular basis to check the status of its components and repla-
ce these when they are not in perfect condition.
For most types of use it is not necessary to grease the pump, except for the O-rings that must
be greased during repairs.
When it is necessary to lubricate the air, do this with detergent-free SAE 10 oil and adjust the air
lubricator to no more than one drop a minute.
In order to obtain the best possible results, ALWAYS USE ORIGINAL
SAGOLA SPARE PARTS that ensure complete interchangeability, sa-
fety and perfect operation.