It is advisable therefore to disconnect the contacts directly from the line supply valve,
or if this is not possible, move the victim away using insulation materials (pieces of
wood or PVC, cloth, leather, etc.).
The victim should be given immediate medical attention and taken to a
hospital.
1.6 - Master data
Please state the machines exact "Model", "Serial number" and "Year of manufac-
ture" when contacting our assistance service. This will help us give you a quick and
efficient response.
We will ask you to state the machine model and serial number whenever you contact
us, so make sure to check this on the data plate, pictured in fig. 1.
(A)
(G)
Fig. n°1
1.7 Protective and safety devices
ATTENTION!
Make sure the safety devices are in good condition and correctly installed before using
the machine.
Check these before each work shift to ensure they are fitted and in order.
If they are not, you should inform the person responsible for maintenance.
- A Element protective cell: this prevents contact with the element and fan which can
seriously wound the operator.
- B Automatic protective device in the case of dry operation:
the machine stops and an error (H2O) message appears on the screen when the
level of the water falls below the minimum permitted (75 mm from the top of the
immersion tank).
- C Disabling device: the machine stops and an error (HIGH) message appears on
the screen when there is a fault with one of the probes and their temperature
readings are different.
LEGEND
(A) = Product code and name
(B) = Power supply
(C) = Motor frequency
(B)
(H)
(I)
(D) = Amperage
(C)
(L)
(D)
(E) = Serial number
(E)
(F) = Barcode
(F)
(G) = Manifacturer
(M)
(H) = International Protection
(I)
= Weight
(L) = Power
(M) = Origin
6