NOTE:
Most devices (motor) require more starting current to start than specified. A short exceed of the
normed power capacity of the machine is possible but if this happens oftener the life time of the
machine will be shortened.
Please consult the performance specifications on the connected electrical devices, these can usually
be found next to the serial or manufacturing number.
Please consider: Some devices, for instance cooling devices need up to 5 times more starting current
than current during the operation.
NOTE:
If the machine is continuously overloaded or if a short circuit occurs, the power supply to the
connected devices is interrupted. In this case, the overload alarm lights up red continuously. If this occurs,
switch off the machine and check the problem.
13.6

Operation

13.6.1

Switch the engine/machine on

NOTE:
If a device is connected to the machine, disconnect it.
13.6.2

Switch the machine off

In case of emergency stop the machine directly with the ON-OFF switch.
Under normal circumstances, switch off the machine as follows:
Shut down the connected devices and disconnect them from the machine.
Let the machine run for some time without connected devices to cool down.
Switch off the machine by putting the ON-OFF switch to position „OFF".
ZIPPER MASCHINEN GmbH
www.zipper-maschinen.at
• Deactivate ECO-Mode. Set the switch to position "0".
• Set the ON-OFF switch (2) to the "ON" position.
• At cold start set the choke lever (3) to position „CLOSE (0)".
• If the engine runs smoothly set the choke lever (3) to position
„OPEN (I)".
• At warm start (the engine was running and is still warm) set
the choke lever (3) to position „OPEN (I)".
If the engine fails to start after 5 attempts, set the choke lever
to position "CLOSE (0)" and try again.
• Start the engine with the recoil starter.
Grab the recoil starter handle (4) and pull it out slowly. The
resistance becomes strongest at a certain point. This point
corresponds to the compression point. Let the rope roll back
a little from this point and then pull it out powerfully.
Slowly return the starter handle (4).
If the engine does not start, try again.
Normally start: 3-4 attempts.