9.2. INSTALLATION
How often do I need to calibrate my ROTOR
Inspider?
To
en
sure accurate measurement, it is necessary
to correctly calibrate
(zero-offset)
It is not
necessary to
zero-offset your power meter
before every ride,
but it
is convenient to do it every
week or two. It must be calibrated when:
-Power meter is installed n the bicycle
-Chainrings are installed or changed.
Calibration is not required after charging the
battery.
Calibrating a second time is recommended after
30 hours of riding.
Read the user manual carefully to successfully
complete the calibration process.
Why do I have to calibrate twice?
The calibration process requires pressing the
calibration button twice on your
ROTOR's INpower technology requires these two
calibration steps because not only force has to be
calibrated, but angle too.
It is very important that you follow the steps
described in the user manual for correct
calibration. This assures an accurate power
measurement.
What are the calibration values?
ROTOR
power meters
requires angle and force
calibration. After the calibration button is pressed
the first time, you must see a value of 1000 on
your device's screen. After the calibration button
is pressed a second time, the screen's value must
be between +/-200. This second calibration value
is specific to each power meter.
the
power meter
o
head unit
.
If I have doubts that I've correctly calibrated my
power meter.
Read the user manual carefully and calibrate the
cranks as explained.
If you have doubts about correct calibration,
repeat the entire calibration process and
.
compare the two values obtained in the last step
of each process. Variations of +/-5 units are normal.
You can calibrate your power meter using either your
head unit, the
User Software
download for free from ROTOR's website, or the
ROTOR Power app for smartphones.
Frequently asked questions
, which you can find and
55