A. Construction and characteristics:
Transportable terrace/garden heater with tank housing.
Casing in steel with powder-coating or stainless steel
Gas hose connections with metal clamp(screw caps for Germany)
Heat emission from reflector
B. Specifications:
Use propane,butane or their mixtures gas only
Max. wattage: 12500 watts
Min. wattage: 5000 watts
Consumption:
APPLIANCE CATEGORY
TYPE OF GAS:
GAS PRESSURE:
OUTLET PRESSURE OF
REGULATOR:
Using the proper regulator according to outlet pressure of regulator as shown in the tabel above..
C.Table of injector:
APPLIANCE
CATEGORY:
TYPE OF GAS:
GAS PRESSURE:
CALOR TOTAL
TOTAL HEAT INPUT
(Hs): (Qn)
INJECTOR SIZE:
The marking,for example,1,75 on the injector,indicates that the size of injector is 1,75mm
The hose and regulator assembly must conform to local standard codes.
Regulator outlet pressure should meet the corresponding gas category in the table of injector.
The appliance requires approved hose in 0,6m length.
I3+(28-30/37)
Butane
Propane
28-30mbar
37 mbar
30mbar
37 mbar
I3+(28-30/37)
Butane
Propane
28-30mbar
37 mbar
13kW (G30:945g/h; G31:929g/h)
1,88 mm for main burner
0,18 mm for pilot burner
I3B/P(30)
I3B/P(50)
Butane,propane
Butane,propane
or their mixtures
or their mixtures
30 mbar
30 mbar
I3B/P(30)
I3B/P(50)
Butane,propane
Butane,propane
or their mixtures
or their mixtures
30 mbar
1,55 mm for main
0,18 mm for pilot
24
I3B/P(37)
Butane,propane
or their mixtures
50mbar
37mbar
50mbar
37mbar
I3B/P(37)
Butane,propane
or their mixtures
50mbar
37mbar
1,65 mm for main
burner
burner
0,18 mm for pilot
burner
burner