Descargar Imprimir esta página

Important; Failures And Operating Modes - IBEA OlivaRex E-5000 Manual De Usuario

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 43
Ordinary/ long term maintenance
MAINTENANCE
Maintenance must be carried out by quali ed personnel, following the prescriptions laid down
in this manual, observing good practice standards and using only original spare parts. It is the
user's obligation to always and in any case comply with the anti-accident regulations, making
use of protective devices and anything else required by the rules of hygiene and safety at work.
IMPORTANT: Every 50 hours of operation, the internal mechanisms of the head must be
lubricated using high temperature gear grease.
To apply the grease, follow the instructions in gure F.
Rotate the head so as to access the rear part ( g. F1) and identify the two holes V.
Unscrew the two screws W as indicated in gure F2. Using a syringe without a needle, as
shown in gure F3, insert the grease through the holes V. Re-tighten the screws W.
STORAGE
In case of prolonged periods of inactivity, exceeding 10 days, the machine must rst be
thoroughly cleaned, then protected, with a waterproof cloth, from dust and humidity and
nally placed in a dry place, protected from the sun and frost. The battery must be disconnect-
ed from the machine when it is not in use. The battery should be stored fully charged and
recharged every 3 months.

Failures and operating modes

Blinking
Steady
Steady
Fast and continuous blinking
1 blink
2 blink
3 blink
4 blink
5 blink
6 blink
7 blink
8 blink
Red LED
Battery is running low - Residual charge about 10%
Battery low - The engine stops and does not restart
Green LED
Normal operation - No failures
High PCB temperature (over 85°C)
FOC error
Overvoltage
Undervoltage
PCB temperature over 110°C
Engine start error
Engine speed error
High current consumption
Software error