OPERATING INSTRUCTIONS
en
11.3
Light spot diagrams
40
O P E R A T I N G I N S T R U C T I O N S | RSB - Roller Sensor Bar
3.0
(0.12)
12.0
14.0
(0.47)
(0.55)
12.0
(0.47)
Figure 11: Mounting bracket P0B
Hex Plug can be rotated based on side channel mounting hole orientation
1
15.0
3.0
(0.59)
(0.12)
Figure 12: Mounting bracket P0C
3.0
(0.12)
20.3
13.5
(0.80)
(0.53)
25.4
(1.00)
Figure 13: Mounting bracket P0D (Mounting between Hex sections)
Side channel to mount adapter
1
mm (inch)
20
(0.79)
1
2
10
(0.39)
0
–10
(–0.39)
–20
(–0.79)
0
40
80
(1.57)
(3.15)
Distance in mm (inch)
Figure 14: Infrared light beam width
Black, 6%
1
1
11.5
(0.45)
11.5
1
(0.45)
25.4
(1.00)
3
120
160
(4.72)
(6.30)
8027085/2022-05-31 | SICK
Subject to change without notice