en | 26 | IR LD 1.0 | Operating instructions
CO₂
Fig. 5:
Warm up cycle
 The IR LD 1.0 will emit a steady
alarm in synchronization with
the flashing of the center circle
(see Fig. 6).
A
CO₂
Fig. 6:
Steady state
"
The IR LD 1.0 is ready to begin
searching for leaks.
SP01502142 | 14.03.2022
i
For optimal performance and
maximum sensitivity, allow
100%
the IR LD 1.0 to operate in
High Sensitivity mode for 5–10
minutes before use.
6.2
After the
warm-up cycle, the
default to High sensitivity and Au-
tomatic reset mode.
6.3
To change the sensitivity level,
press the Sensitivity button (see
Fig. 2; item 6):
Pressing the Sensitivity button
repeatedly will cycle through
the three sensitivity levels (see
Fig. 2; item 6).
i
100%
Sensitivity levels are only
available in Automatic mode.
6.4
The IR LD 1.0 can be set to either
automatically (default) or manual-
ly recalibrate to the ambient level
of refrigerant and reset the alarm
after detection. Both modes al-
low the user to reset the baseline
detection level; which allows for
probing closer to the leak source
without the detector continually
alarming.