Novoferm tormatic T100 DES Manual De Instrucciones Y De Montaje página 27

Control de portón
Ocultar thumbs Ver también para T100 DES:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54
Force measurement process (menu item 48)
Danger of entanglement by the moving door!
WARNING
Force monitoring does not replace the need for
safety measures against the danger of entangle-
ment!
Perform a force measurement process to exactly determine the
switch-off threshold for force monitoring:
1.
Select the value 99 in menu item 48.
ð
The control starts a force measurement process.
2.
Install a test weight on the door (approx. 20 kg are recom-
mended) and completely open and close the door.
3.
The value measured appears on the LED display and is ac-
cepted as switch-off value. The switch-off value can be
changed (double value equals double force).
4.
Remove the test weight and completely open and close the
door again.
Functional force monitoring check
Upon completion of the force measurement process, carry out a
functional check of the force monitoring function. Install the test
weight on the door again for this purpose. The drive must switch
off!
NOTICE
Force monitoring has not tripped during the
functional check
If the force monitoring function has not tripped,
the settings in menu item 48 must be checked.
The force measurement process must be re-
peated.
Duty cycle (menu item 49)
The duty cycle set prevents the drive motor from being over-
heated and avoids damage.
NOTICE
Motor 5.24 with a plastic gearbox
When motor 5.24 with a plastic gearbox is used,
the duty cycle must be set to the value 1 (3~) or
2 (WS, 1~).
Menu 5 Various settings
Smoke and heat extraction function (menu item 55)
Select the corresponding door position in menu item 55. Connect
the fire alarm system to J7 and select the value  9 in menu
item 50.
Selection of the control type (menu item 59)
In menu item  59, various control variants are selected. For cor-
responding settings please refer to the supplementary sheets.
Make sure that the settings are correct
NOTICE
Incorrect settings can cause damage or malfunc-
tion of the control.
Menu 6 Radio settings
Programming the hand-held radio transmitter
Please observe that every hand-held transmitter must be pro-
grammed individually.
You are provided with the possibility of programming 30  radio
codes.
The following encryption types can be programmed: KeeLoq,
12 Bit Multibit. The first code programmed determines the encryp-
tion type.
Start pulse (menu item 60)
1.
Select "Program hand-held transmitter start button" in menu
item 60.
2.
Actuate the button of the hand-held transmitter for opening
the door.
ð
When the code has been programmed, the dot display
on the LED display blinks 5 times.
3.
Go to Exit to complete the setting process.
½ door opening (menu item 61)
1.
Select "Program hand-held transmitter 1/2 button" in menu
item 61.
2.
Actuate the button of the hand-held transmitter for the
½ door opening.
ð
When the code has been programmed, the dot display
on the display blinks 5 times.
3.
Go to Exit to complete the setting process.
Light function (menu item 62)
Select menu item  62 and actuate the light function button of the
hand-held transmitter. When the code has been programmed, the
dot display on the display blinks 5 times.
Deleting radio codes (menu item 63)
To delete all codes programmed, proceed as follows:
1.
Select menu item 63.
2.
Press and hold the 
When all codes have been deleted, the dot display on
the display blinks 5 times.
Menu 7 DU settings
DU functions
At initial operation, the control must be reset to default settings in
menu item  99. The "Opening force limitation" function in the DU
can be selected in menu 4 under menu item 48:
Value = 0
Force limitation off
Value = 1 - 99 Force limitation is active
Protecting the drive against overheating
NOTICE
In order to protect the drive against overheating,
the duty cycle must be set to the value 5 in
menu 4 under menu item 49.
Menu area 71-78 is automatically enabled if a drive with DU func-
tion has been detected.
Wireless RadioBand closing edge
Prior to every operational cycle, the RadioBand system checks
the system function by a test signal and complies with PL c as per
EN 13849-1.
Insert the module to J14 and select the value 4 in menu item 35
and the value  5 in menu item  53. The function of terminal  J3 is
disabled. Also follow the directives given in the instructions for the
RadioBand.
Crush hazard and risk of being struck by the
WARNING
closing door
Observe that sensors connected to J3 do not
have any function.
Test run
When programming has been completed, carry out a test run by
executing all operating functions. When all operating functions
have been executed correctly, the connected door system is
ready for operation.
T100 DES
 button for 5 seconds.
EN - 25

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

T75 de

Tabla de contenido