ADJUSTMENT STEP 3

Test the Safety Reversal System

TEST
• With the door fully open, place a 1-1/2" (3.8 cm) board (or a
2x4 laid fl at) on the fl oor, centered under the garage door.
• Operate the door in the down direction. The door must reverse
on striking the obstruction.
ADJUST
• If the door stops on the obstruction, it is not traveling far
enough in the down direction. Increase the DOWN limit by
turning the DOWN limit adjustment screw counterclockwise
1/4 turn.
NOTE: On a sectional door, make sure limit adjustments do not
force the door arm beyond a straight up and down position.
See the illustration on page 25.
• Repeat the test.
• When the door reverses on the 1-1/2" (3.8 cm) board, remove
the obstruction and run the opener through 3 or 4 complete
travel cycles to test adjustment.

IMPORTANT SAFETY CHECK:

Repeat Adjustment Steps 1, 2 and 3 after:
• Each adjustment of door arm length, limits, or force controls.
• Any repair to or adjustment of the garage door (including
springs and hardware).
• Any repair to or buckling of the garage fl oor.
• Any repair to or adjustment of the opener.
ADJUSTMENT STEP 4

Test the Protector System

• Press the remote control push button to open the door.
• Place the opener carton in the path of the door.
• Press the remote control push button to close the door. The
door will not move more than an inch, and the opener lights will
fl ash.
The garage door opener will not close from a remote if the
indicator light in either sensor is off (alerting you to the fact that
the sensor is misaligned or obstructed).
If the opener closes the door when the safety reversing sensor is
obstructed (and the sensors are no more than 6" (15 cm) above
the fl oor), call for a trained door systems technician.
®
Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
• Safety reversal system MUST be tested every month.
• If one control (force or travel limits) is adjusted, the other
control may also need adjustment.
• After ANY adjustments are made, the safety reversal system
MUST be tested. Door MUST reverse on contact with 1-1/2"
(3.8 cm) high object (or 2x4 laid fl at) on the fl oor.
Without a properly installed safety reversing sensor, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
Safety Reversing Sensor
29
1-1/2" (3.8 cm) board
(or a 2x4 laid flat)
Safety Reversing Sensor