Descargar Imprimir esta página

Programming The Control Unit - Novoferm tormatic T100 DES Instrucciones De Montaje Y De Manejo

Ocultar thumbs Ver también para T100 DES:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
Installation
0
Required tools
1
Installing the control unit
2
Opening the control unit cover
3
Connections
Designation:
J1
START / impulse input
(OPEN / STOP / CLOSE)
J2
Safety photocell, two or four-wire
J3
Closing edge OSE / 8K2 / DW
J4
Emergency-STOP, slack cable, latching
J7
Key switch, pull button
J9
Digital limit switch - motor cable
J10
Connection of add-on controls
J11
Connection of radio receiver
J12
Aerial
J13
Membrane keypad
X1
Mains connection
X2
Mains output L, N (500 W / 230 V)
X3
Protective conductor contact
X5
Floating relay contact 1,
door status relay
X5
Floating relay contact 2,
door status relay
X7
Door operator
X8
24V DC, 200mA
4
Mains connection
The control unit comes ready-wired with a 16A CEE
phase-changer plug and approx. 1 m of cable (see
4a)
.
The unit must be connected to the mains in
!
accordance with the existing power supply
voltage.
5
Motor connecting lead
The connecting lead for the motor and digital limit
switch (DES) is pre-assembled and ready to use -
attach accordingly.
6
Impulse generator connection
6a/6b
- Connection J1 for external control units
Open, Stop and Close.
6c
- Switching sequence Open-Stop-Close, set value
1 in menu 51.
6d
- J1.3 - door half open, J1.4 – door fully open
Connection J7, switching sequence Open-Close
(Menu 50, default setting) also see operating
instructions of the key-operated switch function
The gate must remain visible from
the place of operating it.
7
Photocell connection
The photocell must be correspondingly set/adjusted
in menu 36.
7a
Two-wire photocell LS2
During this process the closing
procedure must not be interfered with,
otherwise the wrong position could be
recorded.
7b
Four-wire photocell LS5 with self-testing
7c
Reflection photocell
If in the menu the frame-fitted photocell has been
selected, the next time the door closes the control
unit automatically initiates a learning run to detect
the position.
8
Safety edge connection
When using impulse control for door closing,
connection of a safety edge is required. Select the
corresponding setting in menu 35.
8a
Optical closing edge OSE
8b
Electrical safety edge 8K2 with a termination
resistor of 8.2 kOhm (value = 1)
8c
Electrical safety edge 8K2 in series connection
with slack rope and wicket door switch (value = 3)
8d
Pressure wave edge and switch with a loop
resistance of 8.2 kOhm (value = 2)
9
Emergency-STOP connection
10
Key switch / pull button connection
When using a key switch / pull button, the desired
function in menu 50 should be selected.
11
Radio remote control
Plug in receiver module (option) at J11 and initiate
the hand transmitter learning procedure in menu 60,
61 or 62.
12
Relay output
2 change-over contacts:
max. 250VAC / 2A or 24VDC / 1A.
24V-output X8: max. 200mA
Selecting the relay function in menu 45 and 46.
If the AR mode has been selected in menu 40 (menu
3 or 4), the function early warning light will be
assigned to X6. The settings in menu 46 will be
ineffective.

Programming the control unit

The programming is menu-driven. Carry out
adjustment of the door in accordance with the
scheme. The following page shows the full extent of
the menu.
Setting the door end-of-travel positions
30 and 31)
!
The door must be spring balanced.
The top and bottom end positions should be set
directly one after the other.
Correcting the slowing-down path (menu 42)
Compensates changes in the closed position
resulting from temperature fluctuations, gearbox run-
in etc.
Level adjustment (menu 43)
Compensates changes in the closed position
resulting from cable elongation or a rise in the floor
level. The Closed end position is adapted by ground
contact of the closing edge guard.
Set the precise closed position beforehand, then set
in menu 43.
The positions taught in menus 31, 34 and 37 are
adapted accordingly in settings 2, 3 and 4.
Spring breakage detection (menu 47)
If the set value is exceeded, error E32 is displayed.
!
After the springs have been renewed,
the door end-of-travel positions need to be reset.
Motor 9.24/5.24: input value = U x weight / 20 kg
Motor 9.20: input value = U x weight / 16 kg
Motor 9.15: input value = U x weight / 15 kg
Example:
Motor 9.24, U = 8 revolutions to open the door
Weight of the door leaf = 150 kg, each of the 2
springs bears 75 kg. Cut-off recommended at 60 kg.
Input value
= 8 x 60 kg / 20 kg =
The quick release requires re-setting,
otherwise spring fracture safeguards
must be connected.
Check of the spring balancing device
Press the button
of menu 47 for 5 sec rather than
only briefly, after the door has been completely
opened and closed once.
The value indicates how the door is balanced:
Motor 9.24/5.24: F (kg) = display value x 20 kg / U
Motor 9.20: F (kg) = display value x 16 kg / U
Motor 9.15: F (kg) = display value x 15 kg / U
U = number of revolutions for one door opening
If the display value ranges between -2 and -9, the
springs are over-tensioned.
The results are only approximate values; a force
measuring run is required to determine the value
more precisely.
When using 6.65DU, the function will be
!
different. Please refer to section "DU
Functions" for more details.
Opening force limit (menu 48)
The door's opening movements are compared with
one another. If the set value is exceeded, the door
stops and F33 is displayed.
Thereafter, the door can only be closed via the
!
dead man's control. Eliminate the reason
for the excessive force being applied, so that
the door can be opened and closed again.
Motor 9.24/5.24: input value = U x weight / 20 kg
Motor 9.20: input value = U x weight / 16 kg
Motor 9.15: input value = U x weight / 15 kg
The results are only approximate values; a force
measuring run is required to determine the value
more precisely.
When using 6.65DU, the function will be
!
different. Please refer to section "DU
Functions" for more details.
Force measuring run
threshold. After value 99 has been entered in menu
48, the control will carry out a force measuring run:
1. Attach a test weight (recommended approx. 20
kg) at the door and open and close the door
completely.
(menus
2. Following that, menu 48 displays the value
which will be imported as cut-off value. This
value can be modified (double value equals
double force).
3. Remove the test weight again and open and
close the door.
ON period (menu 49)
The ON period set will prevent the drive motor from
getting overheated and thus getting damaged.
!
When using motor 5.24 with plastic transmission,
set the ON period at 1 (3~) or 2 (WS, 1~).
RWA (smoke-heat exhaust) function
Set the required door position in menu 55. Connect
fire alarm to J7 and set value 9in menu 50.
Programming the radio remote control
Please note that each hand transmitter must be
individually programmed. It is possible for up to 30
radio codes to be learned. The following functions
can be taught in.
KeeLoq, 12 Bit Multibit. The first code determines the
type.
Selection of the control type (menu 59)
The various control types can be selected from menu
59. Please refer to the supplementary sheets for the
settings.
Start impulse (menu 60)
Enter the menu and press the button on the hand
transmitter for the START function. As soon as the
code has been learned, the incremental display
flashes five times.
24
Half-open position of the door (menu 61)
Enter the menu and press the button on the hand
transmitter for the half-open position. As soon as the
code has been learned, the incremental display
flashes five times.
Light function (menu 62)
Enter the menu and press the button on the hand
transmitter for the light function. As soon as the code
has been learned, the incremental display flashes
five times.
Deleting radio codes (menu 63)
To delete all the learned codes in the menu, press the
oval button and keep it pressed for 5 seconds.
DU Functions (main menu 7)
Reset the control in menu 99 to the factory setting
during the commissioning. The function "Opening
force limit" in the DU can be selected from menu 48:
value = 0, force limit within
value = 1 ... 99, force limit has been activated
!
In order to protect the drive against overheating,
set the operating time to 5 in menu 49.
GB
to determine the cut-off

Publicidad

loading