USER MANUAL IQ
(1) Water and Drainage
Water quality has a remarkable influence on the appearance, hardness and flavor of the ice as well as, in the machines
condensed by water on the life of the condenser.
(2) Connections to the Water Network
Use a flexible food grade pipe.
Pressure should be established between 1 and 6 Bar (14 and 85 psi / 0.1 and 0.6 Mpa).
If pressures overpass such values, install the necessary corrective devices.
ATTENTION: The machine shall be plumbed (with adequate blackflow protection) according to applicable Federal State
and local regulations.
(3) Connection to Drainage
Drainage should be located below the level of the machine, at 150 mm (5.91 inches) minimum.
It is convenient that the drainage pipe is of 30 mm (1.18 in) of interior diameter and with a minimum gradient of 3 cm
(1.18 in) per meter (see figure).
CORRECT
INCORRECT
Descending
Ascending
INCORRECT
(4) Electrical Connection
IT IS MANDATORY TO GROUND THE EQUIPMENT: To avoid possible discharges on individuals or damages to the
equipment, the machine should be grounded pursuant local and/or national regulations as the case may be.
THE MANUFACTURER SHALL BE HELD HARMLESS IN CASE OF DAMAGES ARISING DUE TO THE LACK OF THE GROUND
INSTALLATION.
The machine is supplied with a 6 feet cable of length. In case the supply cable is damaged, it should be replaced by a
cable or a special kit to be furnished by the manufacturer or post-sale service. Such replacement should be performed
by qualified technical service only.
The machine should be placed in such a way as to allow a minimum space between the back and the wall to allow an
easy access and without risks to the cable plug.
It is convenient to install adequate switches and fuses.
Voltage and tension are indicated on the nameplate and in the technical specifications of this manual. Variation on
voltage above the 10% stated on the nameplate could result on damages or prevent the machine start-up.
The line up to the plug should have a minimum section of AWG16.
4