B
Figure #11
Page
-50-
HOW TO OPERATE THE MACHINE
How to Operate the One Touch System ("L Class" models only)
One touch cleaning is a feature on the new Focus Walk-behind
Scrubber. The factory defaults for this setting are two bars of
brush pressure and four bars for solution flow and squeegee in
the down position.
1.
Press and release the green button for all cleaning
functions to begin, see figure #11, item A.
2.
The squeegee and brush head lower to the floor and the
A
vacuum starts. NOTE: The squeegee switch must be in the
center position for the squeegee to operate with the one
touch feature, see figure #11, item B.
3.
The brushes and solution will begin only when you begin to
traverse.
4.
The cleaning will be at the factory default settings, however
you can reprogram these settings to your specifications.
See "Reprogramming One Touch" section below.
5.
To end cleaning process, press the green button again and
solution will stop; brushes will raise; after a short delay
squeegee will raise; and the motor will turn off.
NOTE: It is intended that this be done while traversing. If you
stop and do it, some solution can be left on the floor.
Reprogramming One Touch
If you do not want to use the factory default settings, you may
reprogram the setting by following the procedures below:
1.
Place the machine in the desired scrub condition by using
the one touch and individual switches.
2.
Press and hold the green one touch button until you see the
LCD display flash, then release the button. NOTE: The time
required should be approximately 5 seconds.
3.
When you activate or deactivate the one touch, it will now be
set to your preference for cleaning. These settings will
remain until you disconnect power or reprogram them.
NOTE: When programming one touch, be sure squeegee
is in automatic (middle) position, otherwise you may
program squeegee either up or down all the time.
How to Return One Touch to Factory Default Settings
To restore the factory settings, follow the procedures below:
1.
Press and hold the green one touch button until you see the
LCD display flash two times (5 seconds between flashes),
see figure 11. NOTE: The time required for this will be
approximately 10 seconds.
2.
The settings should be returned to 4 bars of solution and 2
bars of brush pressure. NOTE: The squeegee vac switch
must be in the middle position for default settings to work.
®