Descargar Imprimir esta página

Helo HNST1 Instalación Y Manual De Uso página 45

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 103
User and installation manual HNS-T1
Test result:
See page 6 for steam generator's operation time in hours before decalcification
The steam generator must be placed away from water and moisture (dry room). The room must be well ventilated as
the unit also produces heat. The maximum temperature of the room must not exceed 35°C. Recommended minimum
free space to sides and above the steamer is 30 cm. Adequate space for maintenance should also be planned for in
the placement of the unit. There should be a drain nearby for draining the tank.
The steam generator can be installed freestanding on the floor or on the wall using wall fittings. When using wall
fittings, ensure you use appropriate fittings and screws for the type of construction material of your walls. The steam
generator weighs about 17 kg when filled with water.
When the automatic drain valve is used, it is recommended you use wall installation so an adequate angle can be
ensured for draining of water.
Image of principle of installation
Steam room
Locating the control panel
HNS–T1 model, must be installed outside the steam room.
The thermostat cable is connected to the control panel. See the connection diagram for instructions.(see page 10)
The control panel cable can be extended with similar screened cable, max 50m.
Steam nozzle/nozzles are fitted approximately 200 to 400 mm from the floor underneath a bench or a seat, or onto
the wall so that the hot steam cannot burn anyone's feet. The steam nozzles are aimed towards the floor. When the
nozzles are installed, you must ensure to place them somewhere where nobody can accidentally touch them. The
steam temperature is +100 °C and it can cause injuries on contact.
If children or people with impaired reflexes use the steam room, the steam nozzle must be fitted with a protector that
prevents people from being exposed to the hot steam shower.
The thermostat is installed at about 1,700 mm high, preferably on the wall opposite the door. It is recommended to
seal the thermostat installation hole with appropriate sealing material, so that moisture cannot enter the wall
structures.
The steam room thermometer is installed at such a height that it shows the same reading as the control panel.
On / Off push button can be used for remote starting, the push button can be placed in the steam room or outside
it. For more detailed instructions see page 17.
All manuals and user guides at all-guides.com
<
°
3
dH,
Very soft water.
>
°
4
dH,
Soft water. Installing the decalcification device recommended
>
°
7
dH,
Medium-hard water. Installing the decalcification device recommended
>
°
14
dH,
Hard water. Installing the decalcification device recommended
>
°
21
dH,
Very hard water. Installing the decalcification device recommended
Thermostat
Control panel
Water connection
On/off push button
Steam pipe
Flushing
Power
supply
Generator wall mounting
4
380

Publicidad

loading