SETTING 2: MANUALLY SETTING THE LOWER END LIMIT AND AUTOMATICLY SETTING THE UP END
LIMIT (Product with automatic bottom lock system prohibited):
1- Press the « DOWN » button: the motor will run down automatically if the button is held for 2 sec. Stop the motor
« STOP » button at the desired down limit.
2- If necessary adjust the position with the « UP » and « DOWN » buttons.
3- Press simultaneously on the « STOP » and «UP » buttons: the motor will run up. Press « STOP » button to
stop the motor (Optional).
4- Press 2 s on the « STOP » button to confirm the settings, the motor jogs.
The operation is completed. Go to section §5.
SETTING 3: AUTOMATICLY SETTING THE DOWN & UP END LIMITS (Product with bottom lock system
Prohibited):
1- Press simultaneously on the « UP » and « DOWN » buttons: the motor jogs.
2- Press the « DOWN » button: the motor runs down until the down end limit detection. The motor moves briefly
UP and returns to its down end limit. This indicates the limit is set correctly.
3- Press 2s on the « STOP » button to confirm the settings, the motor jogs.
The operation is completed. Go to section §5.
If the lower end limit does not set automatically after several attempts: Cut the power supply (2 seconds
minimum), repeat the operation 4.1, and then use the setting 2 method.
US
4/12
1
2
+
1
> 2 s
3
2
3
2 s
4
2 s