RECORDING / CONTROLLING / DELETING AN INTERMEDIATE POSITION (IP)
10
Recording:
- Run the motor to the desired position.
- Press 5 seconds on the « STOP » button until
the motor jogs.
The intermediate position should not be recorded less than 2s of running from Up end limit and less than 4s
from down end limit.
Controlling:
- When the motor is already stopped press on the « STOP » button for 0.5 s.
The motor will run to the intermediate position.
Deleting:
Run the motor to the intermediate position. Then press for 5 seconds on the « STOP » button. The intermediate
position is deleted.
When using locks (manuals or automatics), it is not possible to delete the intermediate position.
FUNCTION « MANUAL LOCKS »
11
The fabric can be drawn taut when the product, equipped with manual locks, is at the lower end limit.
Always check to determine whether or not the function is activated/deactivated before locking the
locks and using the function. Failing to do so may lead to damage of the product.
To check whether or not the function is activated:
1
1- Press the « DOWN » button: the motor will run to the down end limit.
2- The latches must be unlocked, then press the « STOP » button:
- If the motor goes to the intermediate position (IP), the fabric tensioning function is not activated.
- If the motor lowers then raises briefly, the fabric tensioning function is activated.
To activate or deactivate this function, the procedure is the same:
For safety reasons, this function can only be accessed via the individual control point in
2 situations:
- After programming the first control and during the next 4 cycles.
- After a single power outage and during the next 4 cycles.
1- Press the « DOWN » button: the motor will run to the
Down end limit.
2- Press simultaneously the « STOP » and « UP » buttons
for 5 seconds, until the motor jogs. The operation is done.
- This function is deactivated by default.
2
X
OK
OK
>>>>>
5 s
IP(§10)
X
>>
OK<< <<
1
2
5 s
2s
IP OK
4s
>> OK
Activation
Deactivation