Example: if JOBS 1 to 50 have been created and the user has entered
number 3 in the submenu «CHn»:
- When the sub-mode is activated and not welding, briefly releasing
the torch button will scroll through the JOBS one by one from the 1st
to the 50th and then loop back again. Here the user displays the JOBS
and chooses the 10.
- Pressing the button for over 0.5s allows to start welding with JOB 10
(first of the sequence) and briefly releasing it loads JOB 11 and then
JOB 12 (these 3 JOBS make the sequence).
- When the welding stops, the JOB 10 is loaded and displayed on the
interface (this saves the user the task of having to show all the JOBS
again).
The HMI will behave with the relevant information:
- The JOB is permanently displayed as well as the parameters (TIG LIFT/HF, 4T, Pulse...).
- The weld cycle is accessible and can be modified (the JOB is adjustable*),
- The menus are accessible and modifiable. Eg:
• JOB 5, amended, SAVE IN / JOB 5, the JOB is overwritten with the new parameters and saved.
• JOB 5, amended, SAVE IN / non-existent JOB, it will be integrated into the current q.L. if, and only if, the new JOB X is a smaller number
than the JOB already entered.
- When currently browsing the welding cycle or one of the two menus, the JOB recall function is disabled.
- During welding, when recalling a JOB of the sequence, the screen displays JOB X for 1s.
* A JOB is changed by action on the interface without saving, the welding is authorised without taking into account the modifications on the JOB
recalled.
OPTIONAL REMOTE CONTROL
• RC-HA2 Analogue remote control (ref. 047679):
An analogue remote control can be connected to the power source via the socket (I-9).
This remote control allows the current to be adjusted from 50% to 100% of the set value. In this setup, all modes and features of the power source
are accessible and configurable.
• Remote control pedal RC-FA1 (ref. 045682):
A remote control pedal can be connected to the power source via the socket (I-9).
The foot pedal allows the current to be varied from minimum to 100% of the current setting. In TIG, the machine only works in 2T mode. Further-
more, the increase and decrease of the current is no longer managed by the power source (inactive function) but by the operator via the foot pedal.
Connection:
1- Connect the remote control to the socket (I-9).
2- The interface automatically detects the remote control and displays a selection of options accessible with the thumbwheel:
rc
no
rc
PEd
rc
Pot
Pressing the thumbwheel confirms the remote control selection, and switches back to welding mode.
Connectivity
The machine is equipped with a female connector for a remote control.
The specific 7-point male connector (optional ref. 045699) can be used to connect the different types of remote control. For wiring, follow the
diagram below.
Type of remote control
Foot pedal
C5
40
Translation of the original
instructions
A command is shown but not active.
Selection of a pedal-type remote control.
Remote control with potentiometer selection.
Manual remote control
Job
11
Job
10
>0.5s
<0.5s
<0.5s
Wire description
10 V
Cursor
Common/Earth
Switch
AUTO-DETECT
ARC ON
REG I
TITAN 231 DC FV
Job
12
>0.5s
Pin
A
G
F
A
B
C
B
E
D
E
D
C
F
External view
G