DISPLAY CURRENT/VOLTAGE DURING WELDING
During welding, the machine measures and displays the welding current and voltage.
After the weld, the average current and voltage values or the energy and duration of the welding bead are displayed until the interface (buttons or
scrollwheel) are touched, if the weld resumes or that a trigger press is not carried out.
Access to the current / voltage or energy / time configuration is available through the menu
AFF
.
ENERGY MODE
This mode (which was developed for welding with DMOS-supported energy control) allows, in addition to the energy display of the weld bead
post-welding, to set :
C_T
- The thermal coefficient
energy displayed is calculated taking into account this coefficient.
- Length of the weld bead
in the display «J» flashes).
TROUBLESHOOTING
This device has a fault monitoring system. In the event of a problem, error messages may be displayed.
If the user needs to open the product, they must turn off the power supply by disconnecting the electrical plug from the socket, and wait two minutes
for safety.
Error code
Thermal protection
US1
A power surge has been detected.
The trigger of the torch is at fault but still
Err
USc
active.
Err
HAD
A defect on the VRD was found.
Err
HAP
A hard fault is detected.
Err
Ebp
A button on the keypad is defective.
A problem with the presence of the
CU
001
cooling unit is detected.
44
Translation of the original
instructions
according to the standard used: 1 for ASME standards and 0.6 (TIG) or 0.8 (MMA) for European standards. The
L
(OFF - mm): if a bead length is registered, then the energy display changes from joules, to joules/mm (the unit
Meaning
Maximum duty cycle reached.
Obstructed air input.
The product has gone into a protective
mode.
The trigger of the torch is defective.
-
A problem has been detected on the
DSP or on the thermal disconnection
of the SAM robotic module.
A button on the keypad is short-cir-
cuited.
The cooling unit was detected by the
product, but then the information was
lost.
SEt
UP
CAUSES
• Wait for the light to go out before conti-
nuing the weld.
• Pay attention to the duty cycle and make
sure the air flows.
Check the wiring of the power outlet and
the tightness of the terminals.
If the overvoltage is only temporary, the
product will resume operation after 15
seconds.
Remove the torch and check if the mes-
sage is still accurate.
If so, torch fault.
If not, check the internal connections.
Contact your distributor.
Check the wiring.
Replace the keypad.
Check the connections between the cooling
unit and the product (connector properly
fitted and plugs securely mounted...).