ENGLISH
2. PUMP DESCRIPTION
C
SOCKET FOR CONNECTING THE REMOTE HAND
(
C1
MAINS CABLE
PLUG
PROTECTION FUSES
F
-
ON
OFF SWITCH I
IG
IR
QUICK RELEASE FEMALE HYDRAULIC COUPLER
IM
TRANSPORT HANDLE
ALARM LED
LA
MT
ELECTRIC MOTOR
PO
HYDRAULIC PUMP
REMOTE HAND CONTROLLER
PC
PF
REMOTE FOOT PEDAL CONTROLLER
/
PS
OIL RELEASE
EMERGENCY BUTTON
QE
ELECTRICAL PANEL
(
ft)
3 METRE
9.8
TF
3. INSTRUCTION FOR USE
3.1) Setting up
– Carry the pump using the handle (IM) and place
on a fl at, stable surface in a dry position.
B
EFORE OPERATING THE PUMP FOR THE FIRST TIME
THE TRANSPORT CAP WITH THE WORKING CAP SUPPLIED
– To avoid oil leakage during transportation, the
pump is equipped with an hermetically sealed cap which must be replaced with the working cap
supplied, for correct operation.
– Remove the transport cap and replace it with the orange working cap (TL) complete with dipstick
for oil level verifi cation, tighten fi rmly.
– Check that the nominal supply voltage corresponds to the value shown on the pump label then
connect to the mains: ON-OFF switch (IG) will light, indicating connection to mains elettricity.
The pump must only be connected to correctly earthed sockets.
– Remove "REMOTE CONTROL" protective cap, connect the remote hand controller to the socket
(C) (see Fig. 4 page 35): tighten the plug (CP) by turning the bezel (G) clockwise until it locks.
– Connect the fl exible hose (TF) to the hydraulic head and to the corresponding female coupler
(IR) on the pump (see Fig. 4 and 5).
(Ref. to Fig. 1, page 3)
+
2
PHASES
EARTH
O
/
/
OIL RESERVOIR
HIGH PRESSURE FLEXIBLE HOSE
/
FOOT PEDAL CONTROLLER
)
TL
,
REPLACE
.
FIG. 2
6