Cleaning The Condenser - ITV ICE MAKERS SPIKA NG 75 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USER MANUAL SPIKA
Below an example to calculate the proper quantity of sanitizer to add to the water, for household bleach 12,5%:
15
15
Bleach to add
=
% dis
12.5
13) Sanitize all surfaces of the ice thickness sensor, water level sensor, shield and water tray applying liberally the
sanitizer solution using a cloth or sponge.
14) Sanitize the interior surfaces of the freezing compartment (including walls, plastic parts of the evaporator,
distributor...) and the front panel applying liberally the sanitizer solution using a cloth or sponge.
15) Return the water tray and shield to their normal positions.
16) Connect power and water supplies.
17) To start a sanitation cleaning cycle, move the ice-wash switch to the WASH position. The machine will drain the
reservoir and refill it. Pour the sanitizer into the water reservoir to get a solution as in the point 12 (the volume in
the water tray is approximately 1.6 gal for MS 880 and 0.8 gal for MS 440).
18) Allow the solution to circulate in the water system for 20 minutes and then set the ice-wash switch to the OFF
position.
19) To purge out the sanitizer solution and residue move the ice-wash switch to the WASH position (drain and refill)
and allow the water to circulate for 5 minutes and then move the switch to the OFF position (drain). Repeat this
operation two more times to rinse thoroughly.
20) Return the panel to their position.
21) Set the ice-wash switch to the ON position (position I) and discard the first two harvests.
CLEANING THE ICE BIN (FOR UNDERCOUNTER MODELS)
1) Disconnect the machine, close water faucet and empty storage bin of ice
2) Use the cleaner/water solution to clean all surfaces of the bin. Use a nylon brush or cloth. Then rinse all areas
thoroughly with clean water.
3) Use the sanitizer/water solution to sanitize all surfaces of the bin. Use a nylon brush or cloth.
4) Rinse with plenty of water, dry, run the machine and open water faucet.

CLEANING THE CONDENSER

(1) Air Condenser
1) Disconnect machine and close water faucet.
2) For undercounter models remove the front grid by pressing the two clips placed at right side (see figure).
Front grid
= 1.2 gr/L
*0.133 = 0.16 oz/gal
14

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido