Astralpool multiparameter
USER MANUAL
4.2
WALL MOUNTING
Install the control unit away from heat sources, in a dry place, without splashing water and protected from
dripping, at temperatures below 40°C. The minimum temperature must not fall below 0°C.
The control unit must be installed, making sure to leave enough space for the cables and connections.
The rear panel of the control unit is provided with 4 holes near the corners for mounting the unit to the wall.
The figure below features the position of the drilling holes and the maximum dimensions of the panel.
280 mm
Floor Level
Figure 9 System wall mounting
If adequate for the support, use the wall plugs supplied, otherwise choose a suitable type. The unit is
supplied already assembled and wired internally.
To ensure optimal support for the system, the wall must be as straight and even as possible.
Drill two holes horizontally aligned at a height that enables the operator to have a correct view of the control
panel and a suitable position for the calibration and control operations.
The recommended height from the floor is about 180 cm or at least at eye level.
The distance between the holes is indicated on the picture above.
Use a spirit level during installation to correctly level the control unit.